Product Type

INTERLOCKED WALL BLOCK

Product Standard

TS EN 771-4

Product Description

KÇS Kipaş Aerated Concrete Interlocking Wall Blocks, produced in accordance with TS EN 771-4 standard and certified by TSE and CE, are used in interior and exterior walls of structures such as flat wall blocks and in interior and exterior walls of masonry buildings.

Interlocking blocks, which reduce thermal bridges, eliminate the need for glue application in vertical joints. This increases application speed and reduces glue consumption.

As KÇS Kipaş Gazbeton, we produce two tongue and groove panels specifically for the exterior facades of buildings, which prevents the heat transfer caused by the masonry mortar by 90%.

Since no masonry mortar is applied to the tongue and groove surfaces, it provides both savings and ease of application.

It provides ease of knitting thanks to its tongue and groove features.

Area of Use

KÇS Kipaş Aerated Concrete Interlocking Wall Blocks, manufactured to TS EN 771-4 standard and certified by the TSE and CE, are used in interior and exterior walls of structures similar to plain wall blocks, as well as in the interior and exterior walls of masonry buildings. Interlocking blocks, which reduce thermal bridges, eliminate the need for glue in vertical joints. This increases application speed and reduces glue consumption.

KÇS Kipaş Aerated Concrete is a mineral-based, completely fireproof wall material with high thermal insulation properties. It is used in the construction of interior and exterior infill walls of buildings, as a load-bearing exterior and interior wall material in masonry structures. It is also suitable for firewall construction.

It is manufactured to a precision of ±1.0-1.5 mm in the TLMB dimensional class. This provides ease and speed of application, as well as plaster savings.

The main features of KÇS Kipaş Aerated Concrete are its high thermal insulation and fire resistance, minimal dimensional deviations, lightness and smooth surfaces.

Because;
When used in appropriate thickness, exterior facades can be constructed in many regions of our country without applying thermal insulation/sheathing on the wall (except for columns and beams) in accordance with the TS 825 Thermal Insulation Rules and Thermal Insulation Regulations in Buildings.

Detail Table

KÇS KİPAŞ AAC LAMP MORTISE BLOCK PRODUCTS TECHNICAL SPECIFICATIONS

Products DIMENSIONS(CM)     Thermal Conductivity Dry Density Compressive Strength Fire Class
  Length Height Width λh 10 dry W/m.K Kg/m³ Kgf/cm² Fireproof
G2/350 50…60 20…25 5…50 0,090 350 23≤ A1 EURO CLASS
*G2/400 50…60 20…25 5…50 0,083 (K.Maraş UTO) 400 25≤ A1 EURO CLASS
*G2/400 50…60 20…25 5…50 0,087 (Söke UTO) 400 25≤ A1 EURO CLASS
G2/500 50…60 20…25 5…50 0,15 500 35≤ A1 EURO CLASS
G2/600 50…60 20…25 5…50 0,16 600 50≤ A1 EURO CLASS